Tools needed
Supplied by customer
2.5mm Hex Key/T-bar
2 each 22mm and 1 each 19mm Open End Wrenches
Adhesive
Loctite 330 kit
Loctite 3463 for washdown areas
Medium strength threadlocker
Loctite 242
Degreaser
Lint free rag
80 grit sandpaper or drill and wire wheel/grinder
Supplied by Augury
Augury Halo Endpoints (EP)
Studs/Mounts
Step 1: Remove the cover
Remove the cover by loosening the cap screws and flip the switch upwards. The self-test then starts. Confirm the self-test passes. (The LED lights will be blinking blue. If it's constant or blinking red, DO NOT USE THE ENDPOINT)
NOTE: The endpoint MUST be placed in the exact position it was previously. If unsure, contact Augury.
Step 2: Clean the machine
Clean the machine surface with sandpaper, a wire wheel, or grinder to remove any residue or paint. Use a degreaser and lint free rag to finish cleaning the machine surface.
Step 3: Attach the appropriate basemount
Use Loctite 242 Threadlocker to attach the appropriate basemount to the sensor. Hand tighten the basemount to the sensor first, then use two 22mm wrenches to tighten.
NOTE: If the endpoint is being mounted through drill and tap method, use a 22mm wrench and a 19mm wrench.
Step 4: Attach the endpoint to the machine
Apply the appropriate glue to the basemount and attach the endpoint to the machine, paying attention to the orientation of the endpoint in relation to the machine.
Step 5: Verify that the endpoint is mapped
Verify that the endpoint is mapped or perform mapping to the endpoint. For more details read the article Map and validate the R4000 endpoint.