Skip to main content

Ranger Pro IoT Networking Requirements

Updated over 4 months ago

The following table defines the network topology, ports, and protocols required to support an Augury system installation.

WiFi (AP) configuration

Setting

Supported configuration

Comments

WiFi type

WEP

WPA-PSK [TKIP], Personal

WPA2-PSK [AES], Personal

SSID

Visible (Not Hidden)

Preferably isolated dedicated network for IoT

Encryption

TKIP

AES

Authentication

PSK

● No other authentication steps to gain access (e.g captive portal)

● The password should be 8-63 characters long

● Password may include 94 special characters, as detailed in thePrintable Characters Table

● In case of a Wi-Fi password change, the user needs to configure the Gateway with the new credentials

Band

2.4Ghz

IEEE 802.11 b/g/n

IP Addressing

IPv4 DHCP or Static IP

A dedicated network (DMZ, VLAN, etc.) is recommended.

RSSI

-70dBm

Minimal Wifi RX signal strength

DNS server

Should be provided by the network

Cellular configuration

Setting

Supported configuration

Comments

SIM

Standard size SIM (large)

APN

As required by the network operator

4G (LTE) only

Outbound Connections

The following ports must be open to enable Ranger Pro systems to communicate with Augury servers.

Port / Protocol

Destination

Description

TCP 443

iot.augury.com (52.177.239.125)

api.augury.com

IoT services

TCP/UDP 655

Upon customer request

35.227.38.87

35.227.23.164

35.197.254.125

35.197.217.254

35.189.119.102

35.196.166.158

Support,Service

UDP/TCP 123

0.pool.ntp.org

1.pool.ntp.org

2.pool.ntp.org

3.pool.ntp.org

or

Customer provided (local NTP server or time.google.com

NTP

TCP 80

13.107.246.55

13.107.246.56

Required, IoT Data Transfer

TCP 8883

solace-prod.mhaas.bakerhughes.com

divigraph-iothub.azure-devices.net

production-iothub.azure-devices.net

20.80.227.212

20.44.17.101

20.253.108.228

20.253.108.230

Required, IoT Data Transfer, MQTT

TCP 22

divi-prod-reverse.westeurope.cloudapp.azure.com

20.13.122.0

Optional, Support Service

TCP/UDP 53

8.8.8.8

8.8.4.4

Required, DNS

TCP 4901

RPCS client node

Optional, only add if RPCS configuration software is used on site.

TCP 502

Modbus client node

Optional, only add if Modbus connection is used on site.

Document Number: PB00039
Revision: A